Model No.: SPS300VAC12000W
Packaging: cartons
Transportation: Air
Payment Type: T/T
Incoterm: EXW
APM 3 phase programmable ac source input 3 phase 4 wire+ground/Y connect ,delivers pure AC and DC power.Users can program voltage and frequency, measure the critical characteristics of the output on its large 5.6" LCD display.It delivers the right solution to simulate all kinds of input condition of UUT to be utilized in R&D and QA.Variable frequency AC Power Supply up to 1000hz.There are more models, 1800W 3 Phase AC Source and 3000W 3 Phase AC Source, 4500W 3 Phase AC Source,6000W Three Phase AC Source System, 15000W Three Phase AC Source System for your reference.
Application Area:
This series is applicable to multiple sectors such as electric, lighting and aviation sectors and it could be applied to enterprise's production test as well.
Product Features:
● 5.6`` large touch color screen, possess complete functions and easy to operate.
● Support for USB data import/export and screen snap from front panel.
● AC+DC mixed or independent output mode for voltage DC offset simulation.
● Capable of setting voltage and current output restriction, support for constant current output mode.
● Capable of setting output slope of voltage and frequency.
● Capable of setting ON/OFF phase angle.
● With reverse current protection to avoid current flowing backward.
● Built-in power meter, which is capable of measuring 5 electrical parameters per phase, including voltage, current, power, etc.
● Support mA current measurement function.
Basic Functions:
1. Adjustable Phase Angle/Slope
Adjustable Phase Angle/Slope is applicable to verification test of ON/OFF inrush current testing. This function is applicable to start inductive or capacitive load with large capacity to avoid high current when instantaneously start the device.
2.High Output Current Crest Factor
The surge current could reach 5-6 times of the rated current, especially suitable for inrush current testing.
3. Output Simulation Sequence and Disturbance Simulation
Capable of simulating power line disturbance simulation test.
Advanced Functions:
1.Built-in IEC Standard Test
Built-in IEC standard test could be recalled directly.
2.3-Phase Operation and Parallel Mode
Support 3-phase operation, 3 units in parallel
Technical Specification:
MODEL | SPS300VAC12000W | ||
INPUT | |||
1 | Voltage | 190~265VAC | |
2 | Frequency | 47~63Hz | |
3 | Phase | 3 Phase,4Wire+Groud/Y Connect | |
4 | Max.Current | 75A | |
5 | Power Factor @220Vac Input ,Full Load | 0.99 Min. Active PFC | |
6 | Effieciency | >87% Max >86% @220Vac,50HZ input/230Vac,50HZ output | |
3-Phase Output Mode | |||
7 | AC Power(Per Phase) | 4000VA | |
8 | AC Power(Total) | 12000VA | |
9 | Max.Current (r.m.s) | 0~150V(L) | 32A |
0~300V(H) | 16A | ||
10 | Max.Current (Peak) | 0~150V(L) | 160A |
0~300V(H) | 80A | ||
Parallel Phase Mode | |||
11 | Max.Current (r.m.s) | 0~150V(L) | 96A |
0~300V(H) | 48A | ||
12 | Max.Current (Peak) | 0~150V(L) | 480A |
0~300V(H) | 240A | ||
13 | Phase | 1 Phase | |
OUTPUT | |||
14 | Total Harmonic Distortion(THD) | <0.5% (Resistive Load) at 15.0 - 70.0Hz and output voltage within the 80 - 140Vac at Low Range or the 160 - 280Vac at High Range <1% (Resistive Load) at 70.1 - 500Hz and output voltage within the 80 - 140Vac at Low Range or the 160 - 280Vac at High Range <1% (Resistive Load) at 501 - 1000Hz and output voltage within the 100 - 140Vac at Low Range or the 160 - 280Vac at High Range | |
15 | Crest Factor(CF) | ≤5 | |
16 | Load Regulation | +/-0.2%FS @15-100HZ(Resistive Load) +/-0.5%FS @ Others Freq.(Resistive Load) | |
17 | Line Regulation | ±0.1V | |
18 | Voltage(AC) (L-N) | Range | 0~300VAC, 150V/300V/Auto Mode |
Resclution | 0.1V | ||
Accuracy | 0.2% of setting +0.4%F.S at Voltage>3V | ||
19 | Phase Angle (Starting/Ending) | Range | 0~359.9° |
Resclution | 0.1° | ||
Accuracy | ±1° @45~65Hz | ||
20 | Voltage(DC) | Range | 0~424VDC |
Resclution | 0.1V | ||
Accuracy | 0.2% of setting +0.4%F.S at Voltage>3V | ||
DC Power | 4000W | ||
Max.Current (L/H Range) (Per Phase) | L 22.6A | ||
H 11.3A | |||
DC Power(Total) | 12000W | ||
Max.Current (L/H Range) (Total) | L 67.8A | ||
H 33.9A | |||
Ripple&Noise(r.m.s) | L <700mVrms @Bandwidth 20HZ to 1MHZ | ||
Ripple&Noise(Peak) | <4000mVp-p @Bandwidth 20HZ to 1MHZ | ||
21 | Current OC Fold Mode | Resclution | 0.1A |
Accuracy | 2.0% of setting +1.0%F.S. | ||
Response Time | <1400ms | ||
22 | Frequency | Range | 15~1000Hz |
Resclution | 0.1Hz(15.0~99.9Hz) ,1Hz(100~1000Hz) | ||
Accuracy | 0.03% of setting | ||
23 | Progrmmable Output Impedance | Not Support | |
24 | Harmonic & Inter-harmonics Simulation | Not Support | |
MEASUREMENT(Per Phase) | |||
25 | Voltage (Per Phase) | Range | AC 0~300VAC |
DC 0~424VDC | |||
Resclution | 0.1V | ||
Accuracy | 0.2% of setting +0.4%F.S. (Notes: Vpeak: 0.6% of setting +1%F.S.) | ||
26 | Frequency (Per Phase) | Range | 15~1000Hz |
Resclution | 0.1Hz(15.0~99.9Hz) ,1Hz(100~1000Hz) | ||
Accuracy | 0.1% of setting | ||
27 | Current* (r.m.s) (Per Phase) | Range | H 0.3A~32A |
M 0.2A~20A | |||
L 0.1A~5A | |||
mA 0.02A~1.5A | |||
Resclution | 0.01A | ||
Accuracy | 0.4%+1.0%F.S. | ||
28 | Current* (PEAK) (Per Phase) | Range | 0A~163A |
Resclution | 0.01A | ||
Accuracy | 0.4%+1.5%F.S. | ||
29 | Power (Per Phase) | Range | 0~4080W |
Resclution | 0.1W | ||
Accuracy | 0.4% of setting +0.3%F.S at PF>0.2, Voltage >5V | ||
30 | Power Apparent | Range | 0~4080VA |
Resclution | 0.1VA | ||
Accuracy | Voltage*Irms,Calculated value | ||
31 | Power Resistive (VAR) (Per Phase) | Range | 0~4080VAR |
Resclution | 0.1VAR | ||
Accuracy | √[(VA)^2-(W)^2],Calculated value | ||
32 | Power Factor (PF) | Range | 0.00~1.00 |
Resclution | 0.01 | ||
Accuracy | W/VA, Calculated value | ||
33 | Harmonic | Range | Not Support |
Extra Function | |||
34 | Slew Rate | Range | AC Voltage 0.001-1200.00V/mS and Disable |
DC Voltage 0.001-1000.00V/mS and Disable | |||
Frequency 0.001-1600.000HZ/ms and Disable | |||
35 | Remote Sense | Range | 5V(RMS), Max. Total power less than rated power |
36 | Cablibration | Firmware-based cablibration through the digital interface or front panel display Noted: Need Factory setting | |
37 | Test Mode | Not Support | |
38 | Graphic Display | 5.6'' Color touch LCD | |
39 | Operation Key Feature | Soft key,Numberic key,Rotary Knob,Support USB disk | |
40 | Rack mount Handles | YES | |
41 | FAN | Temperature Control | |
42 | Protection Circuits | OCP, OVP, OPP, OTP, RCP, PRI_UVP, PRI_OVP, PRI_OTP, PRI_OCP, USB_OCP | |
43 | Interface | Standard USB,RS485,RS232, Option GPIB interface | |
Environmental | |||
44 | Operating Temperature | 0°C to 40°C | |
45 | Storage Temperature | -40°C to 85°C | |
46 | Altitude | 2000m | |
47 | Relative Humidity | 5-95%, non-condensing | |
48 | Temperature Coefficient | 100ppm/°C at Voltage, 300ppm/°C at Current, 100ppm/°C at FREQ | |
Mechanical | |||
49 | Dimensions(W*H*D) | 560x945x700 mm | |
50 | Unit Net Weight | 157.0kg |
Product Categories : Three Phase AC Source System > 12000W Three Phase AC Source System