APM

HomeProductsThree Phase AC Source System15000W Three Phase AC Source SystemAPM medical Grade Power Supply with High Performance
Contact Supplier
Chris Liu

Mr. Chris Liu

Leave a message

APM medical Grade Power Supply with High Performance

$1 - 9999 /Others
Payment Type:
T/T
Incoterm:
FOB
Min. Order:
1 Others
Transportation:
Air
Share:
Chat Now
  • Product Description
Overview
Product Attributes

Model No.SPS300VAC15000W

Supply Ability & Additional Information

TransportationAir

Payment TypeT/T

IncotermFOB

Packaging & Delivery
Selling Units:
Others

Product Introduction: 


APM source focus on medical grade Power Supply,  committing to offer high performance and cheap Programmable Power Supply

The AC source are able to  analog output normal or abnormal powerinput for electrical device to meet test requirements.With reverse current protection to avoid current flowing backward.


There are more models, 1800W 3 Phase AC Source and 3000W 3 Phase AC Source, 4500W 3 Phase AC Source,6000W Three Phase AC Source System, 9000W Three Phase AC Source System for your reference.


Application Area:

This series is applicable to multiple sectors such as electric, lighting and aviation sectors and it could be applied to enterprise's  production test as well.


Product Features:

● 5.6`` large touch color screen, possess complete functions and easy to operate.

● Support for USB data import/export and screen snap from front panel.

● AC+DC mixed or independent output mode for voltage DC offset simulation.

● Capable of setting voltage and current output restriction, support for constant current output mode.

● Capable of setting output slope of voltage and frequency.

● Capable of setting ON/OFF phase angle.

● With reverse current protection to avoid current flowing backward.

● Built-in power meter, which is capable of measuring 5 electrical parameters per phase, including voltage, current, power, etc.

● Support mA current measurement function.


Basic Functions:

1. Adjustable Phase Angle/Slope

Adjustable Phase Angle/Slope is applicable to verification test of ON/OFF inrush current testing. This function is applicable to start inductive or capacitive load with large capacity to avoid high current when instantaneously start the device.

2.High Output Current Crest Factor

The surge current could reach 5-6 times of the rated current, especially suitable for inrush current testing.
3. Output Simulation Sequence and Disturbance Simulation 

Capable of simulating power line disturbance simulation test.


Advanced Functions:

1.Built-in IEC Standard Test
Built-in IEC standard test could be recalled directly.

2.3-Phase Operation and Parallel Mode

Support 3-phase operation, 3 units in parallel



Technical Specification:

 MODEL  SPS300VAC15000W
 INPUT
1  Voltage  190~265VAC
2  Frequency  47~63Hz
3  Phase  3 Phase,4Wire+Groud/Y Connect
4  Max.Current  90A
5  Power Factor
@220Vac Input ,Full Load
 0.99 Min. Active PFC
6  Effieciency  >87%  Max
 >86% @220Vac,50HZ input/230Vac,50HZ output
 3-Phase Output Mode
7  AC Power(Per Phase)  5000VA
8  AC Power(Total)  15000VA
9  Max.Current
 (r.m.s)
 0~150V(L)  46A
 0~300V(H)  23A
10  Max.Current
 (Peak)
 0~150V(L)  184A
 0~300V(H)  92A
 Parallel Phase Mode
11  Max.Current
 (r.m.s)
 0~150V(L)  138A
 0~300V(H)  69A
12  Max.Current
 (Peak)
 0~150V(L)  552A
 0~300V(H)  276A
13  Phase  1 Phase
 OUTNPUT
14  Total Harmonic Distortion(THD)  <0.5% (Resistive Load) at 15.0 - 70.0Hz and output voltage within the 80 - 140Vac at Low Range or the 160 - 280Vac at High Range
 <1% (Resistive Load) at 70.1 - 500Hz and output voltage within the 80 - 140Vac at Low Range or the 160 - 280Vac at High Range
 <1% (Resistive Load) at 501 - 1000Hz and output voltage within the 100 - 140Vac at Low Range or the 160 - 280Vac at High Range
15  Crest Factor(CF)  ≤4
16  Load Regulation  +/-0.2%FS @15-100HZ(Resistive Load) 
 +/-0.5%FS @ Others Freq.(Resistive Load)
17  Line Regulation  ±0.1V
18  Voltage(AC)
 (L-N)
 Range  0~300VAC, 150V/300V/Auto Mode
 Resclution  0.1V
 Accuracy  0.2% of setting +0.4%F.S at Voltage>3V
19  Phase Angle 
 (Starting/Ending)
 Range  0~359.9°
 Resclution  0.1°
 Accuracy  ±1° @45~65Hz
20  Voltage(DC)  Range  0~424VDC
 Resclution  0.1V
 Accuracy  0.2% of setting +0.4%F.S at Voltage>3V

 DC Power
 (Per Phase)

 5000W
 Max.Current
 (L/H Range)
 (Per Phase)
 L 32.6A
 H 16.3A
 DC Power(Total)  15000W
 Max.Current
 (L/H Range) (Total)
 L 97.8A
 H 48.9A
 Ripple&Noise(r.m.s)

 L  <700mVrms  @Bandwidth 20HZ to 1MHZ
 H  <1100mVrms @Bandwidth 20HZ to 1MHZ

 Ripple&Noise(Peak)  <4000mVp-p @Bandwidth 20HZ to 1MHZ
21  Current OC Fold Mode  Resclution  0.1A
 Accuracy  2.0% of setting +1.0%F.S.
 Response Time  <1400ms
22  Frequency  Range  15~1000Hz
 Resclution  0.1Hz(15.0~99.9Hz) ,1Hz(100~1000Hz)
 Accuracy  0.03% of setting
23  Progrmmable Output Impedance  Not Support
24  Harmonic & Inter-harmonics Simulation  Not Support
 MEASUREMENT(Per Phase)
25  Voltage
 (Per Phase)
 Range  AC 0~300VAC
 DC 0~424VDC
 Resclution  0.1V
 Accuracy  0.2% of setting +0.4%F.S.  (Notes: Vpeak: 0.6% of setting +1%F.S.)
26  Frequency
 (Per Phase)
 Range  15~1000Hz
 Resclution  0.1Hz(15.0~99.9Hz) ,1Hz(100~1000Hz)
 Accuracy  0.1% of setting
27  Current*
 (r.m.s)
 (Per Phase)
 Range  H      0.3A~46A
 M      0.2A~20A
 L      0.1A~5A
 mA  0.02A~1.5A
 Resclution  0.01A
 Accuracy  0.4%+1.0%F.S.
28  Current*
 (PEAK)
 (Per Phase)
 Range  0A~188A
 Resclution  0.01A
 Accuracy  0.4%+1.5%F.S.
29  Power
 (Per Phase)
 Range  0~5100W
 Resclution  0.1W
 Accuracy  0.4% of setting +0.3%F.S at PF>0.2, Voltage >5V
30

 Power Apparent
 (VA)
 (Per Phase)

 Range  0~5100VA
 Resclution  0.1VA
 Accuracy  Voltage*Irms,Calculated value
31  Power Resistive
 (VAR)
 (Per Phase)
 Range  0~5100VAR
 Resclution  0.1VAR
 Accuracy  √[(VA)^2-(W)^2],Calculated value
32  Power Factor
 (PF)
 Range  0.00~1.00
 Resclution  0.01
 Accuracy  W/VA, Calculated value
33  Harmonic  Range  Not Support
 Extra Function
34  Slew Rate  Range  AC Voltage      0.001-1200.00V/mS and Disable
 DC Voltage      0.001-1000.00V/mS and Disable
 Frequency       0.001-1600.000HZ/ms and Disable
35  Remote Sense  Range  5V(RMS), Max. Total power less than rated power
36  Cablibration  Firmware-based cablibration through the digital interface or front panel display
 Noted: Need Factory setting

37

 Test Mode  Not Support
38  Graphic Display  5.6'' Color touch LCD
39  Operation Key Feature  Soft key,Numberic key,Rotary Knob,Support USB disk
40  Rack mount Handles  YES
41  FAN  Temperature Control
42  Protection Circuits  OCP, OVP, OPP, OTP, RCP, PRI_UVP, PRI_OVP, PRI_OTP, PRI_OCP, USB_OCP
43  Interface  Standard USB,RS485,RS232, Option GPIB interface
 Environmental
44  Operating Temperature  0°C to 40°C
45  Storage  Temperature  -40°C to 85°C
46  Altitude  2000m
47  Relative Humidity  5-95%, non-condensing
48  Temperature Coefficient  100ppm/°C at Voltage, 300ppm/°C at Current, 100ppm/°C at FREQ
 Mechanical
49  Dimensions(W*H*D)  560x945x700 mm
50  Unit Net Weight  157.0kg

*Note:The tolerance will change slightly in high frequency condition

Product Categories : Three Phase AC Source System > 15000W Three Phase AC Source System

Email to this supplier
  • *Subject:
  • *To:
    Mr. Chris Liu
  • *Email:
  • *Message:
    Your message must be between 20-8000 characters
Send Inquiry
*
*

HomeProductsThree Phase AC Source System15000W Three Phase AC Source SystemAPM medical Grade Power Supply with High Performance
Related Products List

Home

Product

Phone

About Us

Inquiry

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Send