Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Model No.: SPS200VDC24000W-2-19
Brand: APM
Place Of Origin: China
Input Voltage: 190~265VAC
Input Frequency: 47~63Hz
Input Power Max: 28.5KW
Power Factor: ≥0.98
Output Voltage Range: 0~200V
Output Current Range: 0~144A
Output Power Range: 0~24000W
Height: 19U
Warranty: 2 years
Packaging: Cartons
Productivity: other
Transportation: Air
Place of Origin: CHINA
Supply Ability: other
Certificate: CE
HS Code: 850440199
Port: DHL
Payment Type: T/T
Incoterm: EXW
APM offers a wide selection of Auto-Ranging high Power Supply . This DC Source System is a 12U high cabinet combined with max quantity 6 single units, delivering voltage from 200V to 1200V, current range from 24A to 144A,max power 21.6kW.Therefore,the requirement of 200V DC Power Supply as well as other adjustable voltage DC cabinet can be satisfied.
There are more models, 40V DC Source System,75V DC Source System, 120V DC Source System,150V DC Source System, 600V DC Source System, 800V DC Source System for your reference.
Application Area:
This series is applicable to multiple sectors such as electric, lighting and aviation sectors and it could be applied to enterprise's production test as well.
Product Features:
● With accurate voltage and current measurement capability.
● Coded Knob, multifunction keyboard.
● Standard RS232/RS485/USB communication interfaces, LAN and GPIB is optional.
● Remote sensing line voltage drop compensation.
● Equips with LIST waveform editing function.
● Use the Standard Commands for Programmable Instrumentation(SCPI) communication protocol.
● Have obtained CE certification.
Technical Specification:
ltem | MODEL | SYS200VDC24000W | |
INPUT | |||
1 | Voltage | 190~265VAC | |
2 | Frequency | 47~63Hz | |
3 | Phase | 3 Phase,4Wire+Groud/Y Connect | |
4 | Max.Current | 150A | |
5 | Input Power Max | 28.5kW | |
6 | Power Factor at 220VAC Input ,Full Load | 0.98 Min. Active PFC | |
7 | Efficiency | >88% Max @Full Load and Units=4kW Model | |
OUTNPUT (Parallel Mode) | |||
8 | Output Voltage | 0~200V | |
9 | Output Current | 0~144A | |
10 | Output Power | 24kW Max | |
11 | Load Regulation | Voltage | 360mV |
12 | Current | 144mA | |
13 | Line Regulation | Voltage | 0.02%F.S.+30mV |
14 | Current | 0.02%F.S.+15mA | |
15 | Voltage Setting | Range | 0~200V |
16 | Resolution | 1mV | |
17 | Accuracy | 0.1%+0.1%F.S. at 0< Ouput Voltage =<75Vdc 0.05%+0.05%F.S. at 75Vdc< Ouput Voltage =<1200Vdc | |
18 | Current Setting | Range | 0~144A |
19 | Resolution | 10mA | |
20 | Accuracy | 0.1%+0.10%F.S | |
21 | Ripple | Voltage | 300mVp-p/60mVrms |
22 | Current | 150mA(Full Range),60mA(TYP Value) | |
MEASUREMENT (Parallel Mode) | |||
23 | Voltage Setting | Range | 0~200V |
24 | Resolution | 1mV | |
25 | Accuracy | 0.1%+0.1%F.S. at 0< Ouput Voltage =<75Vdc | |
26 | Current Setting | Range | 0~144A |
27 | Resolution | 10mA | |
28 | Accuracy | 0.1%+0.10%F.S | |
OUTNPUT (Series Mode) | |||
29 | Output Voltage | 0~1200V | |
30 | Output Current | 0~24A | |
31 | Output Power | 24kW Max | |
32 | Load Regulation | Voltage | 360mV |
33 | Current | 144mA | |
34 | Line Regulation | Voltage | 0.02%F.S.+30mV |
35 | Current | 0.02%F.S.+15mA | |
36 | Voltage Setting | Range | 0~1200V |
37 | Resolution | 0.1V | |
38 | Accuracy | 0.1%+0.1%F.S. at 0< Ouput Voltage =<75Vdc 0.05%+0.05%F.S. at 75Vdc< Ouput Voltage =<1200Vdc | |
39 | Current Setting | Range | 0~24A |
40 | Resolution | 0.1mA | |
41 | Accuracy | 0.1%+0.10%F.S | |
42 | Ripple | Voltage | 450mVp-p/90mVrms |
43 | Current | 100mA(Full Range),40mA(TYP Value) | |
MEASUREMENT (Series Mode) | |||
44 | Voltage Setting | Range | 0~1200V |
45 | Resolution | 0.1V | |
46 | Accuracy | 0.1%+0.1%F.S. at 0< Ouput Voltage =<75Vdc 0.05%+0.05%F.S. at 75Vdc< Ouput Voltage =<1200Vdc | |
47 | Current Setting | Range | 0~24A |
48 | Resolution | 0.1mA | |
49 | Accuracy | 0.1%+0.10%F.S | |
Extra Function | |||
50 | Remote Sense | Range | 5V(DC), Max. Total power less than rated power |
51 | Comm. Respondence. | 50ms | |
52 | Graphic Display | VFD | |
53 | Operation Key Feature | Soft key,Numberic key,Rotary Knob | |
54 | Rack mount Handles | Yes | |
55 | FAN | Temperature Control | |
56 | Protection Circuits | OCP, OVP, OPP, OTP,FAN | |
57 | Interface | USB, RS485, RS232(Standard); LAN,GPIB(Option) | |
Remote Control Input/Output signal characteristics | |||
58 | Remote Input signal | Not Support | |
59 | Remote output signal | Not Support | |
Environmental | |||
60 | Operating Temperature | 0°C~40°C | |
61 | Storage Temperature | -20°C~70°C | |
62 | Altitude | 2000m | |
63 | Relative Humidity | 10%~90%, non-condensing | |
64 | Temperature Coefficient | 100ppm/°C at Voltage, 300ppm/°C at Current | |
Mechanical | |||
65 | Dimensions(W*H*D) | 600.0*1064.0*700.0 mm | |
66 | Package Dimensions(W*H*D) | 720.0*1240.0*820.0 mm | |
67 | Unit Net Weight | 100.0kg+15kg*N(REF) | |
68 | Accessories Weight | 0.4kg | |
69 | Shipping Weight | 160.0kg+15kg*N(REF) | |
Regulatory Compliance | |||
70 | CE Mark | Installation Overvltage Category II;Class II equipment;indoor use only. |
Product Categories : DC Source System > 200V DC Source System
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.