Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Model No.: SP300VAC4000W
Brand: APM
Input Frequency: 47~63Hz
Output Current Range: 0~160A
Input Voltage: 190~265VAC
Power Factor: ≥0.99
Max.Current: 25A
Output Voltage Range: 0~300VAC
Output Power Range: 0~4000W
Height: 4U
Warranty: 2 years
Packaging: cartons
Productivity: other
Transportation: Air
Place of Origin: CHINA
Supply Ability: other
Certificate: ISO9001/CE/ROHS/CSA/UL
HS Code: 8504401500
Port: DHL
Payment Type: T/T
Incoterm: EXW
Model SP300VA4000W is variable AC Output Power Supply.The user interface features a numeric keypad, rotary knob, a 5.6-inch color LCD display capable of displaying precision ac or dc total 15 electrical parameters simultaneously. All measurements and setting values are concurrently displayed on the screen including a graphical display of the output waveform. Additionally, LAN, USB,and RS232 interfaces are all standard.
Except the 4000W AC Power Supply,it could be also have other power opition for 5000W AC Power Supply,3000W AC Power Supply,kindly check more with the regional sales.
Application Area:
This series is applicable to multiple sectors such as electric, lighting and aviation sectors and it could be applied to enterprise's production test as well.
Product Features:
● 5.6" large touch color screen, possess complete functions and easy to operate.
● Support for USB data import/export and screen snap from front panel.
● AC+DC mixed or independent output mode for voltage DC offset simulation.
● Capable of setting voltage and current output restriction, support for constant current output mode.
● Capable of setting output slope of voltage and frequency.
● Capable of setting ON/OFF phase angle.
● Support for LIST/PULSE/STEP mode, simple time setting and circulation setting, which is suitable for power line disturbance simulation test.
● Built-in power sweeping function.
● Built-in Transient mode.
● Built-in Dimmer function.
● With reverse current protection to avoid current flowing backward.
● Built-in power meter, which is capable of measuring 15 electrical parameters, including voltage, current, frequency, etc.
● Support mA current measurement function.
● Built-in IEC61000-3-3/ IEC61000-3-2/ IEC61000-4-11/ IEC61000-4-14/ IEC61000-4-28/ IEC61000-4-13 standard test required waveform.
● Support up to 2 units in series, 4 units in parallel and 3 units combined to 3-phase power output (optional).
Basic Functions:
1. Adjustable Phase Angle/Slope
Adjustable Phase Angle/Slope is applicable to verification test of ON/OFF inrush current testing. This function is applicable to start inductive or capacitive load with large capacity to avoid high current when instantaneously start the device.
2. High Output Current Crest Factor
The surge current could reach 5-6 times of the rated current, especially suitable for inrush current testing.
3. Transient mode
Transient mode simulates the impact on test object when turn on or turn off transient high power capacity load in power grid.
4. Dimmer Function
Support Dimmer function, which is applicable to conduct speed regulating or dimming verification test for electric motor, lamp and other products.
5. Output Simulation Sequence and Disturbance Simulation
Capable of simulating power line disturbance simulation test.
Advanced Functions:
1.Output Impedance(Applicable to Professional Version)
Support Simulating Output Impedance.
2.Built-in IEC Standard Test(Applicable to Professional Version)
Built-in IEC standard test could be recalled directly.
3. Amplifier Function
The programmable AC Power Source could realize real time output by tail after signal waveform.
4. Harmonics/ Inter-harmonics Generate Simulation and Harmonics Measurement(Applicable to Professional Version)
Up to 40 orders of harmonics components, applicable to interference simulation test.
5. External Control Function
Programmable Ac Power Sources could provide analog input under test simulation of PASS, FALL and RUN status and user can control ON/OFF externally, force to shutdown, reset and upload 7 sets of stored parameters.
6. 3-Phase Operation and Parallel Mode
Support up to 2 units in series, 4 units in parallel and 3 units combined to 3-phase power output.
Technical Specification:
at 220VAC Input , 1Hz at 100~1000Hz, Output & Inter- harmonics 1Hz at 100~1000Hz,
Model SP300VAC4000W
Advanced SP300VAC4000W
Professional INPUT 1 Voltage 190~265VAC 2 Frequency 47~63Hz 3 Phase 1 Phase, 2Wire+Groud 4 Max. Current 25A 5 Power Factor
Full Load ≥0.99 Active PFC 6 Efficiency >87% (Peak)
>86% at 220VAC,50Hz input/230VAC,50Hz output, Full Load OUTPUT 7 AC Power 4000VA 8 Max. Current
(r.m.s) 0~150V(L) 32A 0~300V(H) 16A 9 Max. Current
(Peak) 0~150V(L) 160A 0~300V(H) 80A 10 Phase 1 Phase 11 Crest Factor(CF) ≤5 12 Load Regulation ±0.1%F.S.(Resistive Load) at 15-70Hz
±0.5%F.S.(Resistive Load) at 70.1-1200Hz
Note:1001~1200Hz only available to Professional Version Models 13 Line Regulation ±0.1V 14 Voltage(AC) Range 0~300VAC, 150V/300V/Auto Mode Resolution 0.1V Accuracy 0.2% of setting +0.2%F.S. 15 Voltage(DC) Range 0~424VDC Resolution 0.1V Accuracy 0.2% of setting +0.2%F.S. Max. Power 4000W Max. Current
(L/H Range) L 22.6A H 11.3A Rise time/
drop time <180us 16 Current OC
Fold Mode Resolution 0.01A Accuracy 0.5% of setting +1.0%F.S. Response
Time <1400ms 17 Frequency Range 15~1000Hz Full Range ADJ 15~1200Hz Full Range ADJ Resolution 0.1Hz at 15.0~99.9Hz,
1Hz at 100~1000Hz 0.1Hz at 15.0~99.9Hz, Accuracy 0.03% of setting 18 Programmable Range N/A 0Ω +0mH~1Ω +1mH 19 Harmonic Range N/A 2400Hz MEASUREMENT 20 Voltage Range AC 0~300VAC
DC 0~424VDC Resolution 0.1V Accuracy 0.2% of setting +0.2%F.S. 21 Frequency Range 15~1000Hz 15~1200Hz Resolution 0.1Hz at 15.0~99.9Hz,
1Hz at 100~1000Hz 0.1Hz at 15.0~99.9Hz, Accuracy 0.1% of setting 22 Current
(r.m.s) Range H 0.2A~32A M 0.2A~20A L 0.1A~5A mA 0.02A~1.5A Resolution 0.01A Accuracy H/M 0.4%+0.6%F.S.
L/mA 0.4%+1.0%F.S. 23 Current
(Peak) Range 0.05A~163A Resolution 0.01A Accuracy H/M 0.4%+1.5%F.S.
L/mA 0.4%+1.5%F.S. 24 Power Range 0~4080W Resolution 0.1W Accuracy 0.4% of setting +0.6%F.S. at PF>0.2, Voltage >5V 25 Harmonic Range N/A 2~40 orders GENERAL 26 Parallel Output for 1 Phase Yes, 4 Units Max. (Option: Remote I/O & Parallel, Multiphase Link Card) 27 Series Output for 1 Phase Yes, 2 Units Max. (Option: Remote I/O & Parallel, Multiphase Link Card) 28 Link Output for 3 Phase Yes (Option: Remote I/O &Parallel, Multiphase Link Card) 29 FAN Temperature Control 30 Protection Circuits OCP, OVP, OPP, OTP, RCP, PRI_UVP, PRI_OVP, PRI_OTP, PRI_OCP, USB_OCP 31 Interface USB, RS485, RS232(Standard); LAN,GPIB (Optional) ENVIRONMENTAL 32 Operating Temperature 0°C to 40°C 33 Storage Temperature -40°C to 85°C 34 Noise 73dBA(Max fan speed) 35 Altitude 2000m 36 Relative Humidity 5%~95%, non-condensing 37 Temperature Coefficient 100ppm/°C at Voltage, 300ppm/°C at Current, 100ppm/°C at Frequency MECHANICAL 38 Dimensions(W*H*D) 483*177*649mm 39 Unit Net Weight 29.0kg
*Note:The tolerance will change slightly in high frequency condition.
Product Categories : AC Power Supply > 4000W AC Power Supply
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.