Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Model No.: SPS40VDC12000W-2-13
Brand: APM
Place Of Origin: China
Input Voltage: 190~265VAC
Input Frequency: 47~63Hz
Input Power Max: 15KW
Power Factor: ≥0.98
Output Voltage Range: 0~40V
Output Current Range: 0~360A
Output Power Range: 0~12000W
Height: 13U
Warranty: 2 years
Packaging: cartons
Productivity: other
Transportation: Air,Ocean
Place of Origin: CHINA
Supply Ability: other
Certificate: CE
HS Code: 8504401990
Port: DHL
Payment Type: T/T
Incoterm: EXW
DC Source System is a single output Programmable DC Power Supply which provides with high power density and stable DC output. With built-in voltage and current testing capability, DC Source system can fulfill different kinds of DC power applications.
SCPI protocol is provided for the control through the direct current power of the single output and remote interface with the programmable Smps Power Supply. Single unit of the 2U type DC Power Supplies connected in series or parallel can easily achieve the voltage, current and power extension. This 6U rack system is up to 12kW with output voltage up to 120V when connected in series and output current up to 360A for parallel connection. 9 Volt DC Power Supply is also achievable..
Application Area:
This series is applicable to multiple sectors such as electric, lighting and aviation sectors and it could be applied to enterprise's production test as well.
Product Features:
● With accurate voltage and current measurement capability.
● Coded Knob, multifunction keyboard.
● Standard RS232/RS485/USB communication interfaces, LAN and GPIB is optional.
● Remote sensing line voltage drop compensation.
● Equips with LIST waveform editing function.
● Use the Standard Commands for Programmable Instrumentation(SCPI) communication protocol.
● Have obtained CE certification.
Technical Specification:
ltem | MODEL | SYS40VDC12000W | |
INPUT | |||
1 | Voltage | 190~265VAC | |
2 | Frequency | 47~63Hz | |
3 | Phase | 3 Phase,4Wire+Groud/Y Connect | |
4 | Max.Current | 75A | |
5 | Input Power Max | 15kW | |
6 | Power Factor at 220VAC Input ,Full Load | 0.98 Min. Active PFC | |
7 | Efficiency | >88% Max @Full Load and Units=4kW Model | |
OUTNPUT (Parallel Mode) | |||
8 | Output Voltage | 0~40V | |
9 | Output Current | 0~360A | |
10 | Output Power | 12kW Max | |
11 | Load Regulation | Voltage | 120mV |
12 | Current | 0.36A | |
13 | Line Regulation | Voltage | 0.02%F.S.+30mV |
14 | Current | 0.02%F.S.+15mA | |
15 | Voltage Setting | Range | 0~40V |
16 | Resolution | 0.1mV | |
17 | Accuracy | 0.1%+0.1%F.S. at 0< Ouput Voltage =<75Vdc 0.05%+0.05%F.S. at 75Vdc< Ouput Voltage =<1200Vdc | |
18 | Current Setting | Range | 0~360A |
19 | Resolution | 10mA | |
20 | Accuracy | 0.1%+0.10%F.S | |
21 | Ripple | Voltage | 80mVp-p/12mVrms |
22 | Current | 225mA(Full Range),30mA(TYP Value) | |
MEASUREMENT (Parallel Mode) | |||
23 | Voltage Setting | Range | 0~40V |
24 | Resolution | 0.1mV | |
25 | Accuracy | 0.1%+0.1%F.S. at 0< Ouput Voltage =<75Vdc | |
26 | Current Setting | Range | 0~360A |
27 | Resolution | 10mA | |
28 | Accuracy | 0.1%+0.10%F.S | |
OUTNPUT (Series Mode) | |||
29 | Output Voltage | 0~120V | |
30 | Output Current | 0~120A | |
31 | Output Power | 12kW Max | |
32 | Load Regulation | Voltage | 120mV |
33 | Current | 0.36A | |
34 | Line Regulation | Voltage | 0.02%F.S.+30mV |
35 | Current | 0.02%F.S.+15mA | |
36 | Voltage Setting | Range | 0~120V |
37 | Resolution | 10mV | |
38 | Accuracy | 0.1%+0.1%F.S. at 0< Ouput Voltage =<75Vdc 0.05%+0.05%F.S. at 75Vdc< Ouput Voltage =<1200Vdc | |
39 | Current Setting | Range | 0~120A |
40 | Resolution | 1mA | |
41 | Accuracy | 0.1%+0.10%F.S | |
42 | Ripple | Voltage | 60mVp-p/9mVrms |
43 | Current | 300mA(Full Range),40mA(TYP Value) | |
MEASUREMENT (Series Mode) | |||
44 | Voltage Setting | Range | 0~120V |
45 | Resolution | 10mV | |
46 | Accuracy | 0.1%+0.1%F.S. at 0< Ouput Voltage =<75Vdc 0.05%+0.05%F.S. at 75Vdc< Ouput Voltage =<1200Vdc | |
47 | Current Setting | Range | 0~120A |
48 | Resolution | 1mA | |
49 | Accuracy | 0.1%+0.10%F.S | |
Extra Function | |||
50 | Remote Sense | Range | 5V(DC), Max. Total power less than rated power |
51 | Comm. Respondence. | 50ms | |
52 | Graphic Display | VFD | |
53 | Operation Key Feature | Soft key,Numberic key,Rotary Knob | |
54 | Rack mount Handles | Yes | |
55 | FAN | Temperature Control | |
56 | Protection Circuits | OCP, OVP, OPP, OTP,FAN | |
57 | Interface | USB, RS485, RS232(Standard); LAN/GPIB(Option) | |
Remote Control Input/Output signal characteristics | |||
58 | Remote Input signal | Not Support | |
59 | Remote output signal | Not Support | |
Environmental | |||
60 | Operating Temperature | 0°C~40°C | |
61 | Storage Temperature | -20°C~70°C | |
62 | Altitude | 2000m | |
63 | Relative Humidity | 10%~90%, non-condensing | |
64 | Temperature Coefficient | 100ppm/°C at Voltage, 300ppm/°C at Current | |
Mechanical | |||
65 | Dimensions(W*H*D) | 600.0*736.0*700.0 mm | |
66 | Package Dimensions(W*H*D) | 720.0*910.0*820.0 mm | |
67 | Unit Net Weight | 54kg+15kg*N(REF) | |
68 | Accessories Weight | 0.4kg | |
69 | Shipping Weight | 94kg+15kg*N(REF) | |
Regulatory Compliance | |||
70 | CE Mark | Installation Overvltage Category II;Class II equipment;indoor use only. |
*F.S. represents the maximum value of the output range.
*N stands for the number of installed Power Supply units,and N is greater than 1.
Product Categories : DC Source System > 40V DC Source System
Connecting the cabinet
1. The cabinets can be connected in parallel in order to increase output power.
◆ Maximum 16 units 3U height same model DC power supplies or 6U height same model DC power supplies can be connected via the bus.
◆ 16 units each with a power of 18kW are connected together to a 288kW system.
◆ 16 units each with a power of 36kW are connected together to a 576kW system.
2. Different height cabinets can be connected in parallel.
◆ Use parallel bars to simplify the connection between multiple rack cabinets.
◆ Realized the gapless connection between multiple rack cabinets.
System
Master-slave system configuration page.
Submodule
DC output parameters reading page.
Input Info.
AC input parameters measurement page.
OP Value
AC input protection parameters setting page.
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.